Check exhaust ventilation and roof space ventilation requirements under NCC 2022 Part 10.8, and get a recommended product list for your job.
1
Exhaust Systems
NCC 2022 — 10.8.2
Determines the minimum mechanical exhaust airflow rate required.
2
Roof Space Ventilation
NCC 2022 — 10.8.3 / Table 10.8.3
Roof space ventilation provisions apply to Climate Zones 6, 7 and 8 only.
Measured horizontally — the longest plan dimension of the roof.
Only relevant for pitches of 15° or more — cathedral ceilings require a higher eaves open area.
| Roof Pitch | Eaves Open Area | High Level Open Area |
|---|---|---|
| Less than 10° | 25,000 mm²/m (two opposing ends only) | Not required |
| 10° to less than 15° | 25,000 mm²/m | 5,000 mm²/m |
| 15° to less than 75° (Standard ceiling) | 7,000 mm²/m | 5,000 mm²/m |
| 15° to less than 75° (Cathedral / Raked ceiling) | 25,000 mm²/m (7,000 + 18,000) | 5,000 mm²/m |